4. ²ÎÊýɨÃèÎÊÌâʵÀý£ººã¶¨´Å³¡Á¦¾Ø¼ÆËã
¼ÆËãÈçÏÂͼËùʾÌú¿éËùÊÜÏßȦ´Å³¡µÄ×÷ÓÃÁ¦¡£
ÒªÇó¶ÔÏßȦÖеĵçÁ÷ºÍÌú¿éµÄ¸ß¶È×ö²ÎÊýɨÃ裬¼ÆË㲻ͬÉèÖÃֵʱ£¬×÷ÓÃÁ¦µÄ´óС¡£
1.½¨Ä££¨Model£©
Project > Insert Maxwell 3D Design
File>Save as> Parametric£¨¹¤³ÌÃüÃûΪ¡°Parametric¡±£© Ñ¡ÔñÇó½âÆ÷ÀàÐÍ£ºMaxwell > Solution Type> Magnetostatic ´´½¨ÏßȦ
Draw > Regular Polyhedron£¨´´½¨¶à±ßÐÎÖùÌå1£©
Center Position£¨ÖÐÐĵã×ø±ê£©£º £¨X,Y,Z£©>£¨0, 0, 0£©mm Start Position£¨Æðµã×ø±ê£©£º£¨X,Y,Z£©>£¨1.25, 0,0£©mm Axis£¨¶Ô³ÆÖᣩ£ºZ
Height£¨ÖùÌå¸ß¶È£©£º0.8mm
¶à±ßÐαßÊý£ºNumber of Segments: 36 ½«¶à±ßÐÎÖØÃüÃûΪPolyhedron1
Ñ¡ÖÐPolyhedron1£¨´´½¨¶à±ßÐÎÖùÌå2£© CTRL_C£¬CTRL_V ÐÞ¸ÄÏà¹ØÉèÖÃ
Center Position£¨ÖÐÐĵã×ø±ê£©£º £¨X,Y,Z£©>£¨0, 0, 0£©mm Start Position£¨Æðµã×ø±ê£©£º£¨X,Y,Z£©>£¨1, 0,0£©mm Axis£¨¶Ô³ÆÖᣩ£ºZ
Height£¨ÖùÌå¸ß¶È£©£º0.8mm
¶à±ßÐαßÊý£ºNumber of Segments: 36 ½«¶à±ßÐÎÖØÃüÃûΪPolyhedron2
´´½¨ÏßȦ
Ñ¡ÖÐPolyhedron1£¬Polyhedron2 Modeler > Boolean > Subtract Blank Park: Polyhedron1 Tool Park: Polyhedron2 ½«Polyhedron1ÖØÃüÃûΪCoil
Assign Material > copper£¨ÉèÖòÄÁÏΪͣ©
´´½¨Ìú¿éÄ£ÐÍ Draw > Box
ÈÎÒâ´´½¨Ò»¸ö6ÃæÌå ³ß´ç²ÎÊýÉèÖÃÈçÏ£º
×¢Ò⣺ZSize²ÎÊýµÄֵΪ£º¡°SlugHeight¡±
½«ÁùÃæÌåÖØÃüÃûΪSlug
Assign Material > iron£¨ÉèÖòÄÁÏΪiron£©
´´½¨¼ÆËãÇøÓò£¨Region£© Draw > Region
Padding Percentage£º200%
´´½¨¼¤ÀøµçÁ÷¼ÓÔØÃæ£¨Create Section£© Select Coil
Modeler > Surface > Section Section Plane: YZÆ½Ãæ
Modeler > Boolean > Separate Bodies£¨·ÖÀëÁ½SectionÃæ£© ɾ³ý1¸ö½ØÃæ
Select 1¸ö½ØÃ棬Del
½«Ê£ÏµÄ1¸ö½ØÃæÖØÃüÃûΪ¡°Section1¡±
2.ÉèÖü¤Àø£¨Assign Excitation£© Ñ¡ÖÐÏßȦ½ØÃ棺Section1
Maxwell 3D> Excitations > Assign > Current
Value: AmpTurns
Type: Stranded£¨ÏßÐμ¤ÀøµçÁ÷£©
3.ÉèÖüÆËã²ÎÊý£¨Assign Executive Parameter£© Ñ¡ÖÐ Slug
Maxwell 3D > Parameters > Assign > Force Name: Force 1 Type: Virtual
4.ÉèÖÃ×ÔÊÊÓ¦¼ÆËã²ÎÊý£¨Create Analysis Setup£© Maxwell 3D > Analysis Setup > Add Solution Setup
×î´óµü´ú´ÎÊý£º Maximum number of passes £º 5 Îó²îÒªÇó£º Percent Error: 1%
ÿ´Îµü´ú¼ÓÃÜÆÊ·Öµ¥Ôª±ÈÀý£º Refinement per Pass : 30%
5. ´´½¨²ÎÊýɨÃèÉèÖÃ
Maxwell 3D > Optimetrics Analysis > Add Parametric µã»÷Add£¬´´½¨É¨Ãè²ÎÊý variableÑ¡Ôñ£º SlugHeight linear step
Start =1, Stop =2, Step = 0.5 µã»÷Add >>°´¼ü
½«SlugHeightµÄɨÃèÉèÖÃÌí¼Óµ½Óұ߿հ×À¸
variableÑ¡Ôñ£º AmpTurns £¨ÉèÖð²ÔÑÊýµÄɨÃ裩 linear step
Start =100, Stop =200, Step =50 µã»÷Add >>°´¼ü
½«AmpTurnsµÄɨÃèÉèÖÃÌí¼Óµ½Óұ߿հ×À¸ µã»÷OK.
µã»÷ Calculations×Ӳ˵¥ µã»÷ Setup Calculations
°Ù¶ÈËÑË÷¡°77cn¡±»ò¡°Ãâ·Ñ·¶ÎÄÍø¡±¼´¿ÉÕÒµ½±¾Õ¾Ãâ·ÑÔĶÁÈ«²¿·¶ÎÄ¡£Êղر¾Õ¾·½±ãÏ´ÎÔĶÁ£¬Ãâ·Ñ·¶ÎÄÍø£¬Ìṩ¾µäС˵×ÛºÏÎÄ¿âMaxwell˲̬³¡·ÂÕæÊµÀý(3)ÔÚÏßÈ«ÎÄÔĶÁ¡£
Ïà¹ØÍÆ¼ö£º