Usai Technology Services Co., Ltd.

EN 61347-2-13 Requirement - vibration test 1 h; 1,5 g After the tests: - insulation resistance - dielectric strength test at 35 % of specified value; test voltage - Current or the ohmic component does not deviates by more than 30 % Short-circuit and overload protection Upri: 1.06 times rated voltage or 0.94 and 1.06 times rated supply voltage - used voltage Determined temperature rise in windings and on other parts: - test according to Clause - Primary winding - Limit max - Secondary winding - Limit max - External enclosure - Limit max - Rubber insulation of wiring - Limit max - PVC insulation of wiring - Limit max - Supports - Limit max Fail-safe convertors Remark

Clause I.6.3.3 I.6.3.4 I.7 I.7.1 I.7.2 I.7.3 I.7.4 I.7.5 I.7.5.1 I.7.5.2 I.8 I.8.1 I.8.2 Result N N N N N P 240V X 1.06 = 254.4V P P P P P P P P P N N P P P P N ? ? ? N N N N N N N N P P P P N P

- Upri: 1.06 times rated supply voltage ............. V: - Isec: 1.5 times rated output current ................. A: - time until steady-state conditions t1 (h) .......... : - time until failure t2 (h): < t1; < 5 h .................. : During the test: - no flames, molten material, etc. - temperature rise of enclosure < 150 K - temperature rise of plywood support < 100 K After the test: - electric strength (test voltage; 35 % of specified value); no flashover or breakdown for primary-to-secondary and for primary-to-body - live parts not accessible by test finger through holes of enclosure Insulation resistance and electric strength Conditioned 48 h between 91 % and 95 % Adequate insulation (500 V d.c. for 1 min) between: Live parts and the body -for basic insulation not less >20 M? than 2 M? ........................................................... : Live parts and the body -for reinforced insulation not less than 4 M? .................................................... : Input- and output circuits not less than 5 M? ..... : >20 M? Report No.: S1107787

Page 36 of 39

Usai Technology Services Co., Ltd.

EN 61347-2-13 Requirement Metal parts of class II controlgear which are separated from live parts by basic insulation only and the body not less than 5 M? ........................ : Remark

Clause Result N Metal foil in contact with the inner and outer surfaces of enclosures of insulating material not less than 2 M? ...................................................................... : Electric strength test: 1) Between live parts of input circuits and live parts of output circuits ................................................... : 2) Over basic or supplementary insulation between: a) live parts which are or may become of different polarity ............................................................. : b) live parts and enclosure if intended to be connected to protective earth .......................... : c) accessible metal parts and a metal rod of the same diameter as the flexible cable or cord ........ : d) live parts and an intermediate metal part ........ : e) intermediate metal parts and the body ............ : N P P P P P N N N P P P P N N I.8.3 I.9 I.9.1 I.9.2 I.10 I.10.1 I.10.2 I.11

3) Over reinforced insulation between the body and live parts ............................................................... : No flashover or breakdown occurred Construction Comply with all requirements The distance between input and output terminals shall not be less than 25 mm ............................... : Components Socket-outlets in the output circuit does not accept plugs complying with IEC 60083 and IEC 60906-1 Self-resetting devices shall not be used unless it is certain that there will be no hazards Compliance is checked by connecting the controlgear for 48 h at 1.06 times the rated voltage with the output short-circuited Creepage distances and clearances 1.Insulation between input and output circuits: 2. Insulation between adjacent output circuits: 3.Insulation between terminals for external connection: 4. Basic or supplementary insulation: 5. Reinforced insulation: 6. Distances through insulation: No plug No self-resetting devices N N N P P N N P N N See table 18(16) See table 18(16)

Report No.: S1107787

Page 37 of 39

Usai Technology Services Co., Ltd.

Table Object/part No. Input and output lead wire Components list Manufacturer/ trademark Various Type / model Various Technical data 20AWG or 0.75 2 mm,2C,VW-1,105°C T1A,250Vac T1A,250Vac 0.1uF,300V,110°C Max 2200pF, Min 250V, 125°C Max 2200pF, Min 250V, 125°C Max 2200pF, Min 250V, 125°C 195V ac ,250V dc Approvals VDE Fuse(FS1) (Alternation) X capacitor, (CX1,CX2) Coupling Capacitor(CY1) (Y1 Type) (Alternation) Conquer Bel fuse Various Walsin MST MRT Various AH VDE VDE VDE VDE TDK CD VDE (Alternation) Welson WD VDE Varistor(RV1) Centra Science CNR07D301K CNR10D301K CNR14D301K VDE (Alternation) Jpyin CNR07D301K CNR10D301K CNR14D301K 195V ac ,250V dc VDE (Alternation) Nippon Chemicon CNR07D301K CNR09D301K CNR10D301K CNR14D301K 195V ac ,250V dc VDE Bridge Rectifler(D1) Photo-coupler,(U1) -- Cosmo -- K1010 (Alternation) Lite-on LTV817 (Alternation) Sharp PC123 Choke T2) Choke (T3)(optional) Various Various Various Various Min 2A ,Min 500V Dti=0.5 mm ext dcr≥8 mm int dcr≥8 mm temp=115℃ Dti=0.5 mm ext dcr≥7 mm int dcr≥7 mm temp=110℃ Dti=0.4 mm ext dcr≥8 mm int dcr≥8 mm temp=110℃ 130℃ 130℃ -- VDE VDE VDE -- --

Report No.: S1107787 Page 38 of 39

Usai Technology Services Co., Ltd.

- Long sai Jet Signal Totoku Totoku Furukawa CHANGCHUN PLASTIC -- TF-1597 TF-1597 TIW-2 TIW-3 TEX-E PHENOLI CT375J Min 7.5A Min 700V Class B Class B 130℃

Transistor(Q1) Transformer, T1 Triple insulated wire(provided in T1) Bobbin -- Test with appliance Test with appliance VDE 155℃ 130℃ V-0, 150 °C Phenolic. 130 °C 130 °C V-1 or better 130℃ Min 105℃ VDE VDE VDE VDE VDE UL -- Insulating tape for JINGJIANG YAHUA CO LTD CT T1 Magnet Wire CHANGZHOU DAYANG MW75C WIRE & CABLE CO LTD PCB -- -- -- Capacitor(C6,C7) --

END OF REPORT

Report No.: S1107787 Page 39 of 39

百度搜索“77cn”或“免费范文网”即可找到本站免费阅读全部范文。收藏本站方便下次阅读,免费范文网,提供经典小说教育文库LED灯测试报告 - 图文(8)在线全文阅读。

LED灯测试报告 - 图文(8).doc 将本文的Word文档下载到电脑,方便复制、编辑、收藏和打印 下载失败或者文档不完整,请联系客服人员解决!
本文链接:https://www.77cn.com.cn/wenku/jiaoyu/668443.html(转载请注明文章来源)
Copyright © 2008-2022 免费范文网 版权所有
声明 :本网站尊重并保护知识产权,根据《信息网络传播权保护条例》,如果我们转载的作品侵犯了您的权利,请在一个月内通知我们,我们会及时删除。
客服QQ: 邮箱:tiandhx2@hotmail.com
苏ICP备16052595号-18
× 注册会员免费下载(下载后可以自由复制和排版)
注册会员下载
全站内容免费自由复制
注册会员下载
全站内容免费自由复制
注:下载文档有可能“只有目录或者内容不全”等情况,请下载之前注意辨别,如果您已付费且无法下载或内容有问题,请联系我们协助你处理。
微信: QQ: