77范文网 - 专业文章范例文档资料分享平台

AIAA-2005-565-450Acoustic Testing of the dielectric barrier(5)

来源:网络收集 时间:2021-04-05 下载这篇文档 手机版
说明:文章内容仅供预览,部分内容可能不全,需要完整文档或者需要复制内容,请下载word后使用。下载word有问题请添加微信号:或QQ: 处理(尽可能给您提供完整文档),感谢您的支持与谅解。点击这里给我发消息

推进器的声波特性

1.00E+00 1.00E-01 1.00E-02 A m p litu d e 1.00E-03 1.00E-04 1.00E-05 1.00E-06 1.00E-07 1.00E-08 1.00E-09 0 5000 10000 15000 20000 25000 30000 Frequency (Hz)1.00E+00 1.00E-01 1.00E-02 A m p litu d e 1.00E-03 1.00E-04 1.00E-05 1.00E-06 1.00E-07 1.00E-08 1.00E-09 0 5000 10000 15000 20000 25000 30000 Frequency (Hz)(a) (b) Figure 6: Frequency Spectrum in a sound booth (a) with sound absorbing material removed, (b) with material replaced (sinusoidal forcing voltage of 15 kV, at 5 kHz 45 degrees) Since the plot shown in figure 6b is quite similar to that of the free field, the booth appears to be successful in minimizing reflections as it was designed to do. Therefore, the results from tests taken in the booth are considered an accurate measurement for the direct acoustic emissions from the actuator. The next set of measurements with this first apparatus compared results using different forcing voltages. A sinusoidal forcing voltage at a frequency of 5 kHz was used to drive the 30x8 cm actuator with the glass dielectric material. Data was taken for three forcing voltages, Vppf, of 5, 7, and 10 kV. The measured microphone peak-topeak voltage, Vppm, is plotted versus the angle on a polar plot (see Figure 4) to determine the directional characteristics of the acoustic emissions from the actuator with regard to orientation along its longitudinal axis. Figure 7 shows a polar plot of the peak-to-peak microphone voltage as a function of the orientation angle. The angle at which the maximum peak-to-peak voltage occurs did not change as the voltage was increased. The amplitude difference between the three forcing voltages is large and apparently nonlinear. However, normalized plots (not shown) indicate that the pattern is fairly consistent with a large frontal lobe at approximately 40 degrees above horizontal in the direction of the flow. At the lowest voltage there appears to be a small back lobe.Figure 7: Polar plot of Vmpp, comparing acoustic emissions for different forcing voltages (Vfpp) at 5 kHz In another set of measurements with this first apparatus the size of the actuator surface was changed while maintaining the sinusoidal forcing voltage at 7 kV with a frequency of 5 kHz. Three actuator sizes were used; the original 30x8 cm, and two additional actuators (28x15 cm and 30x4 cm). The polar plot of these results, figure 8, shows the difference in the measured amplitudes of the acoustic emissions with angle. Although the directional pattern of the acoustic emissions does not appear to change much with the actuator size, the magnitude does. Interestingly enough, the smallest actuator (30x4 cm) falls between the other two actuators. 5 American Institute of Aeronautics and Astronautics

百度搜索“77cn”或“免费范文网”即可找到本站免费阅读全部范文。收藏本站方便下次阅读,免费范文网,提供经典小说教育文库AIAA-2005-565-450Acoustic Testing of the dielectric barrier(5)在线全文阅读。

AIAA-2005-565-450Acoustic Testing of the dielectric barrier(5).doc 将本文的Word文档下载到电脑,方便复制、编辑、收藏和打印 下载失败或者文档不完整,请联系客服人员解决!
本文链接:https://www.77cn.com.cn/wenku/jiaoyu/1208781.html(转载请注明文章来源)
Copyright © 2008-2022 免费范文网 版权所有
声明 :本网站尊重并保护知识产权,根据《信息网络传播权保护条例》,如果我们转载的作品侵犯了您的权利,请在一个月内通知我们,我们会及时删除。
客服QQ: 邮箱:tiandhx2@hotmail.com
苏ICP备16052595号-18
× 注册会员免费下载(下载后可以自由复制和排版)
注册会员下载
全站内容免费自由复制
注册会员下载
全站内容免费自由复制
注:下载文档有可能“只有目录或者内容不全”等情况,请下载之前注意辨别,如果您已付费且无法下载或内容有问题,请联系我们协助你处理。
微信: QQ: